Operating data for stainless steel -7 – Hypertherm PAC500 Water Injection Plasma Cutting System User Manual
Page 38

PAC500
Instruction Manual
4-7
4
OPERATION
Operating Data for Stainless Steel
Material
Thickness
Inches
mm
Nozzle and
Swirl ring
Size
inches
Gas Type and
Flowmeter
Setting
%
Injection
Water Flow
Setting
%
Torch to
Work
Distance
Inches
mm
Arc
Voltage
Setting
Volts
Arc
Current
Setting
Amperes
Travel
Speed
ipm
mm/min
.035
1
1/8
3
125
250
450
11430
.075
2
.120
N
2
30
85
1/8
3
130
250
300
7620
1/8
3
3/16
5
135
260
200
5080
1/4
6
Maximum current for this nozzle is 260 amp.
1/4
6
145
260
150
3810
1/8
3
1/4
6
140
300
200
5080
1/4
6
.166
N
2
45
75
1/4
6
145
350
150
3810
3/8
10
1/4
6
150
380
125
3175
1/2
13 Maximum current for this nozzle is 400 amp.
1/4
6
155
400
100
2540
3/4
19
5/16
8
160
400
50
1270
1
25
3/8
10
165
400
30
760
3/4
19
3/8
10
165
500
75
1905
2
25
.187
N
2
45
75
3/8
10
165
550
60
1525
1-1/2
38
3/8
10
170
580
30
760
2
50 Maximum current for this nozzle is 600 amp.
3/8
10
170
600
20
510
2
50
1/2
13
190
700
25
635
3
75
.220
N
2
70
100
5/8
16
200
750
12
305
Maximum current for this nozzle is 750 amp.
Use the brass tapered retaining cap part no. 020034 above 400 amperes.
When cutting materials greater than 1-1/2 inches (40mm) thick, lower the level of water in the water table to
3 inches (75 mm) below the lower surface of the workpiece. Also de-energize the Water Muffler pump to improve
arc penetration.
For cutting thicker plate refer to the chart Operating Data for High Current Cutting on page 4-10.