Sequence of operation

Power OFF

• Connect the gas supply to the filter on the power unit.
• Connect the torch to the power supply.
• Connect the work lead to the workpiece.
• Apply power at the line voltage disconnect box.
• Set the ON/OFF switch (S1) to ON (I)

Set the power switch (S1) to OFF (O).

• The gas solenoid valve (V1) closes.
• The gas flow stops.
• The consumables reseat.

• The arc extinguishes.
• Postflow continues for 10 seconds.

• The arc transfers to the workpeice.
• Move the torch to make a cut.
• The workpiece drops after the cut.
• Release the plasma start trigger on the

hand torch or the remote start switch
for the machine torch.

• The gas solenoid valve (V1) opens.
• The gas flow starts.
• The torch nozzle and electrode

separate.

• The pilot arc starts.

• Position the torch above the workpiece.
• Pull the plasma start trigger on the hand torch or

press the remote start switch for the machine torch.

The power circuits are ready.

• The gas solenoid valve (V1)

closes.

• The gas flow stops.

• Set the gas pressure (see the

Setup

section in the Operator Manual).

• Select the desired cutting amps with

the current adjustment knob.

The gas solenoid valve (V1)
opens to purge the system and
to allow the setting of pressure.

• Turn the current adjustment knob fully counterclockwise,

to the gas test position.

• Check the gas pressure setting.

• The power ON LED and the gas pressure LED illuminate

green, indicating system is ready for operation.

• Fault LEDs should be extinguished (see

Troubleshooting

guide for more information).