Controls and indicators, Indicator leds, Powermax1250 – Hypertherm Powermax1250 Service Manual User Manual
Page 36: Indicator leds maintenance, Service manual 3-3
![background image](https://www.manualsdir.com/files/789794/content/doc036.png)
4
Controls and indicators
6.0
BAR
5.0
4.0
PSI
80
70
5060
60
40
AMPS
80
25
V
AC
+
_
Current
(amps)
adjustment
knob
Mode switch
Indicator
LEDs
Pressure
gauge
Pressure
regulator
ON (I) / OFF (O)
switch (S1)
Green power ON LED
When illuminated, indicates that power is applied to the system and the power switch is ON ( I ).
Gas
pressure
LED
Yellow:
When flashing, indicates that the gas pressure is below 60 psig (4.1 bar) for cutting, or 40 psig
(2.8 bar) for gouging.
Green: When illuminated, indicates that there is acceptable gas pressure for torch operation.
Note: This LED should illuminate when the power is ON ( I ).
Yellow
torch cap
LED
When illuminated, indicates that the retaining cap is loose or not installed.
Note: Turn OFF (O) the power, correct this fault condition, then turn ON (I) the power to extinguish the
LED.
Yellow
temperature
LED
When illuminated, indicates that the power supply’s temperature is too hot.
Red
fault
LED
When illuminated, indicates that a fault condition exists, which prevents system operation.
Yellow
low line voltage
LED
When illuminated, indicates that line voltage is below 170 VAC or above 680 VAC. On CE units, it can
also indicate a missing phase.
AC
V
Indicator LEDs
MAINTENANCE
powermax1250
Service Manual
3-3