SAFETY, INTRODUCTION & SPECIFICATIONS
Page 1-4
HT2000/MAX200 Water Muffler
Instruction Manua
l
SPECIFICATIONS
Pump*
I
nput Power:
# 031006 .................................................... Pump (3/4 DL) assembly with motor, 2
HP, 3500 RPM 240/480, 3 PH, 60 Hz
# 031088 .................................................... Pump (3/4 DL) assembly with motor,
2HP, 3500 RPM 380-415V, 3 PH, 50 Hz
# 031089 .................................................... Pump (3/4 DL) assembly with motor,
2HP, 3500 RPM 600V, 3 PH, 60 Hz
Maximum Working Pressure ....................
100 psig
Duty ............................................................
Continuous
Direction of Rotation .................................
Clockwise (viewed from motor end)
Output.........................................................
9-11 GPM
Weight ........................................................
85 lbs. (includes base and pump
contactor box)
Dimensions ................................................
19" (H) x 11" (W) x 17" (D) (includes
base and pump contactor box)
* Refer to the Appendix for additional pump specifications.
Pump Contactor
# 003017 ..................................................... Contactor, Size 00, 120 VAC