beautypg.com

Extension cords, Minimum gauge extension cord – Delta 23-589 User Manual

Page 7

background image

7

EXTENSION CORDS

Use proper extension cords. Make sure your extension
cord is in good condition and is a 3-wire extension cord
which has a 3-prong grounding type plug and a 3-hole
receptacle which will accept the tool’s plug. When using
an extension cord, be sure to use one heavy enough to
carry the current of the tool. An undersized cord will
cause a drop in line voltage, resulting in loss of power
and overheating. Fig. 12, shows the correct gauge to use
depending on the cord length. If in doubt, use the next
heavier gauge. The smaller the gauge number, the
heavier the cord.

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC TOOLS

Ampere Volts Total Length of Gauge of

Rating Cord in Feet Extension Cord

0-6 120 up to 25

18 AWG

0-6

120 25-50 16 AWG

0-6 120 50-100 16 AWG
0-6 120 100-150 14 AWG
6-10 120 up to 25 18 AWG
6-10 120 25-50 16 AWG
6-10 120 50-100 14 AWG
6-10 120 100-150 12 AWG
10-12 120 up to 25 16 AWG
10-12 120 25-50 16 AWG
10-12 120 50-100 14 AWG
10-12 120 100-150 12 AWG
12-16 120 up to 25 14 AWG
12-16 120 25-50 12 AWG
12-16 120

GREATER THAN 50 FEET NOT RECOMMENDED

Fig. 12

Fig. 10

Fig. 11

2. Grounded, cord-connected tools intended for use on
a supply circuit having a nominal rating less than 150
volts:

This tool is intended for use on a normal 120-volt circuit
and has a grounded plug that looks like the plug
illustrated in Fig. 10.

If a properly grounded outlet is not available, a temporary
adapter, shown in Fig. 11, may be used for connecting the
3-prong grounding type plug to a 2-hole receptacle. The
temporary adapter should be used only until a properly
grounded outlet can be installed by a qualified electrician.
The green colored rigid ear, lug, or the like extending from
the adapter must be connected to a permanent ground
such as a properly grounded outlet box cover. Whenever
the adapter is used, it must be held in place with a metal
screw.

NOTE: In Canada, the use of a temporary adapter is
not permitted by the Canadian Electric Code.

WARNING: IN ALL CASES, MAKE CERTAIN
THE RECEPTACLE IN QUESTION IS PROPERLY

G R O U N D E D . I F Y O U A R E N O T S U R E H AV E A
CERTIFIED ELECTRICIAN CHECK THE RECEPTACLE.

1 .

A l l g r o u n d e d , c o r d - c o n n e c t e d t o o l s :

In the event of a malfunction or breakdown, grounding
provides a path of least resistance for electric current to
reduce the risk of electric shock. This tool is equipped
with an electric cord having an equipment-grounding
conductor and a grounding plug. The plug must be
plugged into a matching outlet that is properly installed
and grounded in accordance with all local codes and
ordinances.

Do not modify the plug provided - if it will not fit the outlet,
have the proper outlet installed by a qualified electrician.

Improper connection of the equipment-grounding
conductor can result in risk of electric shock. The
conductor with insulation having an outer surface that is
green with or without yellow stripes is the equipment-
grounding conductor. If repair or replacement of the
electric cord or plug is necessary, do not connect the
equipment-grounding conductor to a live terminal.

Check with a qualified electrician or service personnel if
t h e g ro u n d i n g i n s t r u c t i o n s a re n o t c o m p l e t e l y
understood, or if in doubt as to whether the tool is
properly grounded.

Use only 3-wire extension cords that have 3-prong
grounding type plugs and 3-hole receptacles that accept
the tool’s plug, as shown in Fig. 10.

Repair or replace damaged or worn cord immediately.

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

GROUNDING BLADE
IS LONGEST OF THE 3 BLADES

HOLES

GROUNDED OUTLET BOX

GROUNDING

MEANS

ADAPTER

HOLES