Groth 1402 User Manual
Page 5
1402revb.doc
4
At tank pressure less than 80% of set
pressure, upper dome pressure should be
about equal to tank pressure and the vent
should be bubble tight. Minimal leakage
may occur between 80% and 90% of set
pressure.
At set pressure, the upper dome pressure
should be less than 50% of set pressure
and the vent should be flowing freely.
At 110% of set pressure, the lower dome
pressure should be greater than 75% of
set pressure, the upper dome should be
less than 10% and the vent should show no
leakage. The vent should be bubble tight
above 110% of set pressure.
Figure 2
When all conditions have been met, install
the pilot on the valve by connecting the
tubing to the sense, upper dome and
lower dome ports. When pressure is
applied to the valve, test all connections
with a soap solution.
# DESCRIPTION
MATL
1 Cap,
Adjustment
Screw
316
2 Screw,
Adjustment
316
3 Nut,
Jam
316
4 Bonnet,
spring
316
5 Button,
spring
316
6 Spring
316
7 Vent
Aluminum
8 Bolt,
hex
316
9 Button,
spring
316
10 Plate,
retainer
316
11 Body
316
12 Spool
316
13 Seat
insert
316
14 O-Ring Elastomer
15 O-Ring Elastomer
16 Seat
316
17 Rod,
actuator
HDPE
18 Rivet,
pop
316
19 Plate,
diaphragm
316
20 Bolt,
hex
316
21 Actuator
housing,
upper
316
22 Bolt,
hex
316
23 Nut,
hex
316
24 Washer,
lock
316
25 Gasket FEP
26 Diaphragm FEP
27 Actuator
housing,
lower
316
28 Elbow,
male
316
29 Washer,
flat
316
30 O-Ring Elastomer
31 Connector,
male
316
32 Nut,
jam
316
33 Spacer,
diaphragm
Nylon
= Included in Soft Goods Kit
Elastomer Soft
Goods
Kit
Buna-N K1402BP
EPR K1402EP
FFKM K1402KP
Fluoropolymer K1402VP