beautypg.com

Groth 1402 User Manual

Page 5

background image

1402revb.doc

4


At tank pressure less than 80% of set
pressure, upper dome pressure should be
about equal to tank pressure and the vent
should be bubble tight. Minimal leakage
may occur between 80% and 90% of set

pressure.
At set pressure, the upper dome pressure
should be less than 50% of set pressure

and the vent should be flowing freely.
At 110% of set pressure, the lower dome
pressure should be greater than 75% of
set pressure, the upper dome should be
less than 10% and the vent should show no
leakage. The vent should be bubble tight

above 110% of set pressure.


Figure 2

When all conditions have been met, install
the pilot on the valve by connecting the
tubing to the sense, upper dome and
lower dome ports. When pressure is
applied to the valve, test all connections
with a soap solution.

# DESCRIPTION

MATL

1 Cap,

Adjustment

Screw

316

2 Screw,

Adjustment

316

3 Nut,

Jam

316

4 Bonnet,

spring

316

5 Button,

spring

316

6 Spring

316

7 Vent

Aluminum

8 Bolt,

hex

316

9 Button,

spring

316

10 Plate,

retainer

316

11 Body

316

12 Spool

316

13 Seat

insert

316

14 O-Ring Elastomer
15 O-Ring Elastomer
16 Seat

316

17 Rod,

actuator

HDPE

18 Rivet,

pop

316

19 Plate,

diaphragm

316

20 Bolt,

hex

316

21 Actuator

housing,

upper

316

22 Bolt,

hex

316

23 Nut,

hex

316

24 Washer,

lock

316

25 Gasket FEP
26 Diaphragm FEP
27 Actuator

housing,

lower

316

28 Elbow,

male

316

29 Washer,

flat

316

30 O-Ring Elastomer
31 Connector,

male

316

32 Nut,

jam

316

33 Spacer,

diaphragm

Nylon

 = Included in Soft Goods Kit


Elastomer Soft

Goods

Kit

Buna-N K1402BP

EPR K1402EP

FFKM K1402KP

Fluoropolymer K1402VP