Desa C36EMW User Manual
Page 5

- 4 -
For more information, visit www.desatech.com
OUTSIDE AIR KIT (MODEL AK-6)
The installation of an outside air kit should be performed 
during the rough framing of the fireplace due to the nature of 
its location. Outside combustion air is accessed through the 
mobile home floor (Refer to AK-6 Installation Instructions for 
details). In some instances, a wall installation is required (see 
Figure 5). Note: An AK-6WAI Air Kit must be ordered when 
a sidewall installation is required (see accessories on page 12). 
See page 10, figure 25 for instructions on how to operate the 
air kit. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
FAN KIT ASSEMBLY (BK3)
A fan kit assembly is preinstalled in this fireplace. Use of 
blowers or fans other than manufactured by DESA voids the 
warranty. The fan is operated by pressing the rocker switch 
located at the lower right hand corner of the fireplace face. 
Fan kit electrical connections are made through the electrical 
cover plate located on the side of the fireplace as shown in 
figure 6a. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
FAN KIT WIRING INSTRUCTIONS
i.
Loosen the strain relief by turning the plastic screw 
counterclockwise. 
ii.
Remove electrical cover plate (with strain relief) 
from the fireplace by removing the two sheet metal 
screws as shown in figure 6a. 
iii.
Slide power source wiring through the strain relief 
opening and electrical cover plate and make all the 
necessary connections. 
iv.
Slide all wiring connections in the electrical housing 
as shown in figure 6b. 
v.
Secure the electrical cover plate with screws 
previously removed. 
vi.
Tighten strain relief plastic screw.
NOTE: Electrical housing and cover plate have sharp edges, 
wear protective gloves. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
CHIMNEY PIPE
The DESA chimney system consists of 12, 18, 24, 36 and 48 
inch, snap-lock double-wall pipe segments, planned for 
maximum adaptability to individual site requirements. Actual 
lengths gained after fitting overlaps must be taken into 
consideration (lineal gain) and are given in the lineal gain 
chart (see figure 7). 
There are two vent kits available, which have been specially 
designed for common installations in manufactured (mobile 
homes): MW8K (8’ Vent Kit) and MW9K (9’ Vent Kit). The 
contents of these kits are listed under accessories on page 12. 
Most chimney systems for manufactured houses require a 
standard straight installation as described in this section. If an 
uncommon offset installation is required, see page 10. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Important: If the height of the chimney assembly exceeds 
requirements for transportation of the home, the chimney 
installation may be completed after the home is sited. 
Note: the termination must always be installed after the home 
is sited. 
Figure 5 OUTSIDE AIR KIT
Figure 6b ELECTRICAL HOUSING
Figure 6a FAN SWITCH AND STRAIN RELIEF
Figure 7 LINEAL GAIN