beautypg.com

Clearances, Hexamples – Dometic RM2500 User Manual

Page 8

background image

CLEARANCES

Minimum clearances in inches to combustible materials are

G. Top 0

K. Side 0
L: Bottom 0
M: Rear 1
N: See example below

Clearance M between the rearmost part of the refrigerator and
the wall behind the refrigerator
Clearance N on top of the condenser is related to the minimum

ventilation height

See Fig 11 and examples below

Fig.1 1

Refrigerator Overall product Installation product Recess

Distance between

model dimensions dimensions dimensions top of condenser

and top of

Height Width Depth Height

Width Depth Height Width Depth refrigerator

A B

C h

W

d H

W D e

inch

30 3/8 21 11/16 22 1/16

20 1/4 20 3/8 29 3/4 20 1/2 21 3/8 1 1/4

RM2400 inch

32 15/16 23 24 11/16 32 1/8 21 9/16 22 15/16 32 5/16 21 13/16 23 15/16 1 1/4

RM2500 inch

40 13/16 23 24 11/16 40 21 9/16 22 15/16 40 3/16 21 13/16 23 15/16 1 1/4

RM2600 inch

52 23 24 11/16 51 3/16 21 9/16 22 15/16 51 3/8 21 13/16 23 15/16 1 1/8

RM2800 inch

57 15/16 24 15/16 24 11/16 57 1/8 23 7/16 22 15/16 57 1/2 23 13/16 23 15/16 1 1/8

This method of installation and these clearences will give you adequate space for servicing and proper installation.

d

e

h

EXAMPLES

The clearance N for the RM 2300 model is derived at in the
following way.

Installation with upper and lower side vents
N= Minimum ventilation height 37 minus installation height

29 9/16 plus distance between condenser top and refringera-
tor top 1 114

in: N=37-29 9/16+1 1/4=8 11/16 inches
mm: N=940-751+32=221 mm

Installation with roof vent and lower side vent

N=Minimum ventilation height 31 minus installation height
29 9116 plus distance between condenser top and refrigera-
tor top 1 114 plus distance between roof surface and roof vent
cap 5 114

in: N=31 -29 9/16+1 1/4+5 1/4=7 15/16 inches
mm: N=787-751+32+134=202 mm

Fig.1 2

View from above

This manual is related to the following products: