beautypg.com

Troubleshooting, Continued – Desa SDVBPD User Manual

Page 31

background image

112126-01B

For more information, visit www.desatech.com

For more information, visit www.desatech.com

31

31

OBSERVED PROBLEM

Burner does not light after pilot is lit

Delayed ignition burner

Burner backfiring during combustion

Slight smoke or odor during initial operation

Burner system produces a whistling noise
when burner is lit

Glass soots

Burner system produces a clicking/ticking
noise just after burners are lit or shut off

Remote does not function

REMEDY

1. Clean burner (see Cleaning and

Maintenance, page 29) or replace burner
orifice

2. Contact local propane/LP or natural gas

company

3. Reconnect leads (see Wiring Diagram,

page 33)

4. Replace thermopile
5. Replace gas valve

1. Contact local propane/LP or natural gas

company

2. Clean burner (see Cleaning and Main-

tenance, page 29) or replace burner orifice

1. Clean burner (see Cleaning and

Maintenance, page 29) or replace burner
orifice

2. Replace damaged burner
3. Replace gas control

1. Problem will stop after a few hours of

operation

1. Turn gas control knob to LO position and

let warm up for a minute

2. Operate burner until air is removed from

line. Have gas line checked by local pro-
pane/LP or natural gas company

3. Clean burner (see Cleaning and

Maintenance, page 29) or replace burner
orifice

1. Adjust the log set so that the flame does

not excessively impinge on it

2. Inspect the opening at the base of the

burner to see that it is NOT packed with
any type of material

3. Follow venting configuration instructions

in owner’s manual

1. This is common. If noise is excessive,

contact qualified service person

1. Replace 9-volt batteries in receiver and

remote control

TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Burner orifice clogged

2. Inlet gas pressure is too low

3. Thermopile leads disconnected or im-

properly connected

4. Thermopile is defective
5. Gas valve is defective

1. Manifold pressure is too low

2. Burner porting or orifice clogged

1. Burner orifice is clogged or damaged

2. Damaged burner
3. Gas regulator defective

1. Residues from manufacturing processes

and logs curing

1. Turning gas control knob to HI position

when burner is cold

2. Air in gas line

3. Dirty or partially clogged burner orifice

1. Flame impingement on logs

2. Debris around burner air mixer

3. Improper vent configuration

1. Metal expanding while heating or con-

tracting while cooling

1. Battery is not installed or battery power

is low

TROUBLESHOOTING

This manual is related to the following products: