Fulgor Milano CH 1004 ID TS User Manual
Page 36

36
37
GB
Automatic heat-up function
When the automatic heat-up function
is activated the wattage of the cooking
zone is at 100% for a certain heat-up time
which is dependent on the setting selected
(continuous).
At the end of the heat-up time the electronic
control switches back to the preselected
simmering setting.
Starting process of the automatic heat-
up
- The control is ON and a cooking zone will
be selected
- When the power level 9 is reached
the automatic heating is activated
through a further press of the slider in
correspondence with the maximum value.
- The required power level is selected by
means of the slider and the selected
value is shown on the display.
- At this point, you can select the level
required for the continuation of the
cooking using the Slider area. The symbol
“A” appears 3 seconds after the button is
released, alternating with the continuation
level.
- The continuation level can be changed
within 15 seconds from activation without
disabling the precooking boost. So, you
must select the cooking area and then set
the corresponding cooking area.
- If the selection takes place after 15
seconds:
You can select a higher continuation level;
this implies that the precooking time will
automatically be aligned to the currently
selected continuation level.
Cooking
level
Precooking
Boost A
[min]
Maximum
operating
time [h]
0
0
0
u
0
6
1
1
6
2
3
6
3
4,8
5
4
6,5
5
5
8,5
4
6
2,5
1,5
7
3,5
1,5
8
4,5
1,5
9
0,2
1,5
Residual heat indicator
It is meant to indicate to the user that the
glass ceramic has a dangerous touch
temperature in the circumference of a
cooking zone. The temperature will be
determined following a mathematical
model and the remaining residual heat
will be indicated by means of “H” on the
corresponding 7-segment display.
Heating up and cooling down will be
calculated dependent on
• The selected setting (“0” to “9”)
• The ON/OFF time of the relays
• After switching OFF the cooking zone
the respective display shows “H” until
the assigned cooling zone temperature
is mathematically in an uncritical level. (<
60°C).
Automatic switch-off (limited operating
time)
Maximum operating time is defined for each
hob zone. The maximum operating time
depends on the selected cooking level (see
table). Once the maximum operating time