Troubleshooting – Fronius Selectiva Plus (one-phase) User Manual
Page 44

14
Troubleshooting
Troubleshooting
Cause:
Phase failure
Remedy:
Check the mains lead
Cause:
Electrolyte circulation pump defective
Remedy:
Check electrolyte circulation pump and replace if necessary
Cause:
Battery undervoltage
Remedy:
Check parameter settings and battery voltage
Cause:
Battery overvoltage
Remedy:
Check parameter settings and battery voltage
Cause:
Charging time exceed in I1 phase
Remedy:
Check parameter settings and check battery for defects
Cause:
Charging time exceed in U1 phase
Remedy:
Check parameter settings and check battery for defects
Cause:
Overvoltage on the battery (only when recharging)
Remedy:
Check parameter settings and battery voltage
ERROR 401 -420
Cause:
Charger faulty
Remedy:
Contact After-Sales Service