LocalNet connec-
tion socket
A standardised 10-pin connection socket is available for the LocalNet option. A remote
display or a relay board can be connected to the LocalNet connection socket.
Option for pro-
tection against
undesired star-
ting
The option for protection against undesired starting can be used to control protective
devices that carry out a specific action if the charger is switched on.
A 1-pin or 2-pin option for protection against undesired starting can be implemented as
required.
Important! While the charger is connected to the mains supply, contacts 1/3 are closed.
Important! While the charger is connected to the mains supply, contacts 1/2 and 4/5
are closed.
Important! The option „Protection against undesired starting - 2-pin with change-over
contact“ MUST NOT be operated on two different circuits.
Fig. 9 Protection against undesired starting 1-pin
wiring diagram
Fig. 10 Protection against undesired starting 2-pin
wiring diagram
1
2
3
(A)
* 50 V / 8 A DC
(A)
1
2
3
4
5
6
* 50 V / 8 A DC
(A) Protection against undesired starting control lines
*
max. contact rating