beautypg.com

Maintenance parts list, Troubleshooting guide – DeVillbiss Air Power Company MGP-4600 User Manual

Page 14

background image

14

PROBLEM

CAUSE

CORRECTION

Engine will not start

1. Low on fuel or oil.

2. Ignition switch in "Off" position.

3. Faulty spark plug.

4. Choke in wrong position.

5. Fuel shut-off valve in closed

position.

6. Unit loaded during start-up.

7. Spark plug wire loose.

1. Add fuel or oil.

2. Turn to "ON" position

3. Replace spark plug.

4. Adjust choke accordingly.

5. Open fuel shut-off valve.

6. Remove load from unit.

7. Attach wire to spark plug.

1. Faulty receptacle.

2. Circuit breaker kicked out.

3. Defective capacitor.

4. Faulty power cord.

1. Replace.

2. Depress and reset.

3. Have Service Center replace

capacitor.

4. Repair or replace cord.

No electrical output

1. Overload

2. Faulty cords or equipment.

1. Reduce load.

2. Check for damaged, bare, or

frayed wires on equipment.
Replace.

Repeated circuit breaker tripping

1. Generator overloaded.

2. Insufficient ventilation.

1. Reduce load.

2. Move to adequate supply of fresh

air.

Generator overheating

MAINTENANCE PARTS LIST

Qty.

1
1
2
1
4
4
1
2
2
1
1

Part No.

GS-0231
GS-0029
SSP-499
GS-0027
SSN-51
SSF-990
GS-0028
GS-0033
GS-0036
GS-0234
GA100

Description

Air Filter
Fuel Line
Fuel Line Clamps
Gas Tank
Gas Tank Washers
Gas Tank Screws
Gas Gap
Isolators
Isolators
Spark Arrester
Wheel/Handle Kit

Contact the DeVilbiss Air Power Company Customer Service Department

1-800-888-2468 Ext.2

For Authorized Service Center nearest you

TROUBLESHOOTING GUIDE