beautypg.com

Stop, De f – Dolmar HT-2556 D User Manual

Page 13

background image

13

D

E

F

STOP

Checking the muffler bolts /

cleaning the exhaust outlet

Caution:
Do not tighten the muffler bolts when the engine is hot!
The muffler bolts (6) are directly accessible so they can be

checked for tightness. If loose, hand-tighten (caution: do not

over-tighten).
Regularly clean the exhaust outlet (7) with a suitable tool.

Checking the ignition spark

Use insulated pliers to hold the loose spark plug (5), with the

spark plug cap firmly attached, against the engine housing (away

from the spark plug hole!).
Put the ON/OFF (I/O) switch in the “I” position.
Pull the starter cable hard.
If the function is correct, an ignition spark must be visible near

the electrodes.

CAUTION: Use only the following spark plug: NGK BPMR

7A.

Replacing the spark plug

CAUTION:
Do not touch the spark plug or plug cap if the engine is

running (high voltage).
Switch off the engine before starting any maintenance work.

A hot engine can cause burns. Wear protective gloves!
The spark plug must be replaced in case of damage to the

insulator, electrode erosion (burn) or if the electrodes are very

dirty or oily.
Pull the plug cap (4) off the spark plug. Use only the combination

wrench supplied with the saw to remove the spark plug.
Electrode gap
The electrode gap must be 0,6 - 0,7.

This manual is related to the following products: