beautypg.com

Installation – Desa BG30PT User Manual

Page 14

background image

www.desatech.com

114683-01B

14

2. Pressurize supply piping system by either

opening propane/LP supply tank valve for

propane/LP gas or opening main gas valve

located on or near gas meter for natural gas

or using compressed air.

3. Check all joints from gas meter for natural gas

(see Figure 17) or propane/LP supply tank for

propane/LP gas, to equipment shutoff valve

(see Figure 18). Apply a noncorrosive leak

detection fluid to all joints. Bubbles forming

show a leak.

4. Correct all leaks at once.
PRESSURE TESTING HEATER GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 16,

page 13).

2. For natural gas open main gas valve located

on or near gas meter. For propane/LP gas open

propane/LP supply tank valve.

3. Make sure control knob of heater is in the OFF

position.

4. Check all joints from equipment shutoff valve

to thermostat gas valve (see Figure 17 or 18).

Apply a noncorrosive leak detection fluid to

all joints. Bubbles forming show a leak.

5. Correct all leaks at once.
6. Light heater (see Operating Heater, starting

on page 15). Check all other internal joints for

leaks.

7. Turn off heater (see To Turn Off Gas to Appli-

ance, page 16 or 17, depending on your model

heater).

8. Replace front panel.

Figure 18 - Checking Gas Joints for

Propane/LP Gas

Equipment Shutoff Valve

Propane/LP
Supply Tank

Thermostat Gas Valve

Figure 17 - Checking Gas Joints for

Natural Gas

Equipment Shutoff Valve

Gas
Meter

Thermostat Gas Valve

INSTALLATION

Continued

This manual is related to the following products: