Power connection – Formax FD 260-20 User Manual
Page 10

6
3. POWER CONNECTION
WARNING
BEFORE PLUGGING THE FD 260-20 INTO AN
OUTLET, CAREFULLY READ THE FOLLOWING
INFORMATION ABOUT VOLTAGES, FUSES AND
THE POWER CORD.
3.1 Safety
The FD 260-20 can connect to any power distribution
system, including the European IT Power System. Because
the European IT Power System does not have a grounded
neutral leg, the FD 260-20 uses protective fusing in both
the neutral and hot supply lines of power.
WARNING
A BLOWN FUSE IN THE NEUTRAL LEG COULD
MEAN INTERIOR PARTS OF THE FD 260-20
REMAIN AT A HAZARDOUS VOLTAGE. ALWAYS
UNPLUG THE POWER CORD BEFORE REMOVING
COVERS FROM THE FD 260-20.
3.2 Line Voltage
The FD 260-20 is rated for continuous operation using a
variety of supply voltages. Possible line voltages are 240V,
220V, 120V and 100V at 50 or 60 Hz. The manufacturer
configures the FD 260-20 to operate with the voltage
requested by the customer.
CAUTION
VERIFY THE CORRECT VOLTAGE SETTING
BEFORE PLUGGING THE FD 260-20 INTO AN
OUTLET.
Read the current voltage setting through the VOLTAGE
SELECTOR WINDOW on the CONTROL BOX. (Refer to