Installation – Formax FD 4400 User Manual
Page 6
2
INSTALLATION
Burster Unpack and Assembly
CAUTION: Lifting should not be attempted by less
than four people.
1. Remove bands which hold cardboard box to
wooden pallet. Remove cardboard box.
2. Remove burster top supports.
3. Remove (4) carriage bolts: (2) on infeed end of
burster and (2) outfeed end. NOTE: Leave carriage
bolts in place on center burster support.
4. Remove (4) foam blocks.
5. With allen wrench supplied, unfasten four
retaining bolts which hold machine to the board
immediately below it. NOTE: Center burster support
is not fastened to burster.
6. Attach burster feet to burster. (Fig. 1)
7. Remove burster cabinet from its carton. Note the
Location of holes on top of cabinet.
8. Set burster on cabinet, lining up holes in table with
holes in burster frame. (Fig.2)
NOTE: Burster will line up evenly on all sides of the
table.
9. Add 1/4-20 x 1 1/2 locating screws (included),
to underside of table, screwing up into burster
frame.
Pump Installation
CAUTION: two people should unpack and install
pump.
1. Unpackage and mount pump to the fl oor of
the base. Orient the pump so that the blower is at
the rear and the vacuum is toward the front of the
base. Position the pump to the right side of the base
aligning it with the mounting holes in the fl oor and
fans as shown in Fig. 3. Insert mounting bolts and
secure.
Fig 3
Blower
Mounting Bolts
Vacuum
Do not destroy shipping cartons or materials until
machine has been inspected for damage, missing
parts, and proper operation.