Gestra smk 22, Gestra smk22-51, Technical data – Flowserve SMK 22 User Manual
Page 6
6
Fig. 1
Fig. 2
Fig. 3
GESTRA SMK 22
MADE BY GESTRA
PMA 10bar - TMA 150°C - PMX 6bar
DN15 - 1.4435 - QA .... - Charge: ....
GESTRA SMK 22
MADE BY GESTRA
PMA 10bar - TMA 185°C - PMX 6bar
DN15 - 1.4435 - QA .... - Charge: ....
GESTRA SMK22-51
MADE BY GESTRA
PMA 10bar - TMA 185°C - PMX 6bar
DN15 - 1.4404 - QA .... - Charge: ....
Technical Data
The trap body must not be subjected to pulsating loads. The dimensional allowances for corrosion and
anti-corrosive additives reflect the latest state of technology.
Sizing
Corrosion resistance
If the steam trap is used for the intended purpose, its safety is not impaired by corrosion.
Name plate / Marking
The pressure / temperature ratings are indicated on the trap body / the name plate.
For more information see GESTRA data sheets and Technical Information.
According to EN 9 the name plate and the valve body indicate the type and design:
■
Name / logo of the manufacturer
■
Type designation
■
Pressure class PN or Class
■
Material number
■
Max. temperature
■
Max. pressure
■
Flow direction
■
Stamp on trap body, e. g. specifies the quarter and the year of production
(Example:
st
quarter 2007).
1
07