Operation (cont.), Maintenance, Lv1 lockout and vent valve – Flowserve LV1 Lockout and Vent Valve User Manual
Page 2: Namur accessory bolt chart, How to specify, How to order, Bill of material

© 2002, Flowserve Corporation, Printed in USA
Automax Valve Automation Systems
Installation, Operation and Maintenance Instructions
Flowserve Corporation
765 South 100 East
1978 Foreman Dr.
Flow Control Division
Provo, Utah 84606
Cookeville, TN 38501
www.flowserve.com
Phone: 801 373 3028
Phone: 931 432 4021
Operation (cont.)
Locking spool shaft in block and bleed position prevents
air pressure from operating the actuator. The intent of
this application is to satisfy OSHA requirements for
control of hazardous energy. With air supply to actuator
blocked, the actuator cannot be operated. The valve
mounted to the actuator is effectively “locked out” from
automatic operation.
Temperature: -20 F to 180
o
Pressure: 20 psig to 120 psig
Media: Dry or lubricated non-corrosive gas
compatible with nitrile/viton seals.
Estimated c
v
: 1.75
Maintenance
The LV1 module is factory lubricated for long life.
Should any problems arise with the LV1, consult factory.
If the valve is to be stored for extended periods of
time, periodically operate the spool to keep seals from
taking a set.
NAMUR Accessory Bolt Chart
Bill of Material
Item
Material
Body
Aluminum, Anodized
Spool
Aluminum, Anodized
Endcap
Aluminum, Anodized
Seals
Nitrile, viton
Knob
Plastic
Other NAMUR accessories:
• EC1
- Sandwich mount flow control-one
direction.
• FCDA
- Sandwich mount flow control-dual
direction for DA actuators.
• FCSR
- Sandwich mount flow control-dual
direction for SR actuators.
• APS1
- Air purge system for spring return
actuators sandwich mount with A25N
solenoid valve.
• APS2
- Air purge system for spring return
actuators Namur mount for remote/line
mount solenoid valves.
• NPT1
- 1/4” NPT adapter plate.
• A25N
- NAMUR mount solenoid valve.
Note:
see appropriate IOM’s for additional
information on above NAMUR accessories.
How to Specify
The lockable block and bleed valve shall be an
Automax LV1 module, capable of being sandwich
NAMUR mounted with other NAMUR mount
accessories. The body shall be anodized aluminum.
Spool shall have extension shaft with knob and hole
capable of accepting a standard lock. In normal
position, valve shall allow free air flow. In locked
position, valve shall block external pressure, and vent
actuator pressure with internal air purging of the
cylinder bore during manual gear operation.
How to Order
Order part number LV1 with appropriate NAMUR mount
bolt kit from chart at right.
Example:
To order LV1 to be sandwich NAMUR mounted
with A25N solenoid valve, order
LV1 and NBK55.
LV1 Lockout and Vent Valve
LV1
FC#
APS1 APS2
NPT1 A25N
Bolt Kit
Bolt Kit
Bolt Kit
√
√
NBK40
NBK25
NBK40
√
√
√
NBK50
NBK65
√
√
NBK60
NBK50
NBK60
√
√
NBK55
NBK45
NBK55
√
√
√
NBK70
NBK80
√
√
√
NBK65
NBK55
NBK65
√
√
√
√
NBK80
NBK90
√
√
√
NBK75
NBK85
FC1 / FCDA FCSR
B00058-4 (AUTO-17) 3/02