beautypg.com

Flowserve Lockout Module User Manual

Lockout module, Installation instructions, Operation

background image

Flowserve Corporation

765 South 100 East

Phone: 801 373 3028

Flow Control Division

Provo, Utah 84606

Facsimile: 801 489 2228

Automation Business Unit

www.flowserve.com

Email: [email protected]

© 2001, Flowserve Corporation, Provo, UT

Automax Valve Automation Systems

Installation, Operation and Maintenance Instructions

Lockout Module

Reference Dimensions

Dim.

LOM1 LOM2 LOM3

A

1.63

2.13

2.75

B

2.34

3.93

6.01

C

3.00

4.96

7.31

D

1.62

3.00

4.76

E *

0.53

0.78

1.06

F *

1.16

1.53

1.81

G

0.37

0.57

0.71

H

2.21

3.89

6.01

* (4) places centered on housing

Installation Instructions

The Automax Lockout Modules allow simple mechanical

lockout to new and existing Automax SuperNova valve/

actuator assemblies. Three models of the Lockout Module

mount directly to the SNA063 through the SNA200, as well

as the N63 through the N250, and the A75 through the

A250. The Lockout Module provides a compact mechanical

lockout assembly which when properly implemented will

satisfy OSHA Standard 1910.47, “The Control of Hazard-

ous Energy.” The Lockout Module mounts directly between

a standard valve mounting kit and a SuperNova actuator,

requiring only a special coupler for the specific valve/actua-

tor combination. This allows for easy field retrofit of

a mechanical lockout device to existing valve/actuator as-

semblies.

Note: The Automax Lockout Module is not

suitable for valves requiring a constant positive

shut-off torque to ensure sealing.

To install:

1. Note valve position, open or close. Move valve to

desired lockout position. The actuator should be in

a corresponding position.

2. Apply a thread-locker, Locktite 242 or equivalent

to the mounting studs, and mount studs to actuator.

3. Mount standard valve mounting kit to valve.

4. Install Lockout coupler to valve stem, properly

orienting coupler for desired actuator position.

5. Position Lockout Module as desired on top of

mounting kit. Place actuator over Lockout Module,

aligning coupler and actuator pinion.

6. Tightens nuts until snug. Stroke actuator several

times to properly align coupler.

7. With actuator and valve in desired locked out

position, loosen nuts and rotate Lockout

Module

about valve stem axis, until the

hole in the Lockout

coupler aligns with the slots in the Lockout Module

housing.

8. Insert the Lockout pin through the Lockout

coupler, to hold Lockout Module in position while

tightening bolts. Tighten mounting nuts to actuator.

Note: When locking out a high-performance

butterfly valve, or other valves with “quick

opening” characteristics, bias the lockout

module housing against the lockout pin. To

lockout a HPBV in the closed position, rotate

housing CW against pin to keep valve from

opening CCW.

9. Remove Lockout pin from coupler and insert into

storage brackets on the side of Lockout Module

housing.

Operation

The Lockout pin may be stored and locked in the storage

brackets extruded into the Lockout housing.

To lock out a valve, position valve in desired setting. The

hole in the Lockout coupler should align with the slots in

the Lockout housing. Insert the Lockout pin through the

hole in the Lockout coupler, and apply a lock to the end of

the pin extending from the other side of the Lockout hous-
ing.

WARNING: Do not stick foreign objects, such as fingers,

screwdrivers etc. into Lockout hole. Serious injury may

result. Use only Lockout pin supplied with Lockout Module
to lock out actuato

r.

LMR0022-1 (AUTO-19) 01/11

PAGE 1 OF 2