Flowserve SX-Series SuperNova User Manual
Supernova sx-series, Travel stop adjustments, Both directions
Flowserve Corporation
765 South 100 East
Phone: 801 373 3028
Flow Control Division
Provo, Utah 84606-6160
Facsimile: 801 489 2228
Automation Business Unit
www.flowserve.com
Email: [email protected]
© 2001, Flowserve Corporation, Provo, Utah
Automax Valve Automation Systems
Installation, Operation and Maintenance Instructions
Travel Stop Adjustments
The SuperNova Series actuators have unique, travel stop adjust-
ments in both the clockwise and counterclockwise directions. All
actuated valves require accurate travel-stop adjustments at both
ends of the stroke to obtain optimum performance and valve seat
life. The accumulation of tolerances in the adaption of actuators to
valves is such that there must be a range of adjustment for both
ends of the stroke to achieve the expected performance.
Ball and Plug Valves require precise adjustment at the open (CCW)
position to protect the seat from the flow media and the closed
(CW) position to assure absolute shut-off.
Butterfly Valves require precise adjustment at the closed position
to assure full shut-off, to prevent disc overtravel and damage to the
seat at the closed position and to assure maximum flow in the open
position.
Tandem Valves, where two valves are operated in tandem through
a single solenoid valve (eg., a 3-Way configuration), absolutely
require precise adjustment at both ends of the stroke to assure the
seating of both valves.
Stop Adjustments and Locations
View the actuator with the Air Ports facing you.
All actuators are factory lubricated for life, but still should be
protected from the elements and stored indoors until ready for
use. The ports of the actuator are plugged as supplied from the
factory. If actuators are stored for a long period of time prior to
installation, the units should be stroked periodically to prevent the
seals from taking a set.
Prior to assembly, check the mounting surfaces, the stem adaptor
and the bracket to assure proper fit. Manually open and close
the valve to insure freeness of operation. Be sure the valve and
Automax actuator rotate in the same direction and are in the
same position (i.e., valve open, actuator open). Secure the valve
with the stem vertical. Bolt the bracket to the valve and place the
stem adaptor on the valve stem. Position the actuator over the
valve and lower to engage the stem adaptor to the actuator shaft.
Continue to lower until the actuator seats on the bracket mount-
ing surface. In order to align the bolt holes, it may be necessary
to turn or stroke the actuator a few degrees and/or adjust the
actuator’s travel stops. Bolt the actuator to the bracket.
After consulting the valve manufacturer’s recommendations,
adjust the travel stop bolts of the actuator for the proper open and
closed valve positions. Pneumatically stroke the actuator several
times to assure proper operation with no binding of the stem
adaptor. If the actuator is equipped with an UltraSwitch or other
accessories, adjust them at this time.
To prolong actuator life use only clean, dry plant air. Lubricated
air is not required, however it is recommended particularly for
high cycle applications. Do not use lubricated air with positioners.
Both Directions
Actuator
Fail
Clockwise
Counterclockwise
Type Position (CW)
(CCW)
Double Acting
Left End Cap
Right End Cap
Spring Return
CW
Left End Cap
Right End Cap
Spring Return
CCW*
Right End Cap
Left End Turn
*The pistons are rotated 180° for CCW fail position
SuperNova SX-Series
Endcap Screw
Adjustment Bolt
Spring
Actuator
Socket Size
Socket Size
Color Code
SX050 4mm
3mm
white
SX063
5mm
4mm
lt. green
SX085 6mm
5mm
blue
SX100 6mm
6mm
red
SX115 6mm
6mm
yellow
SX125 8mm
6mm
grey
SX150
8mm
8mm
dk. green
LMR0021-1 (AUTO-6) 11/01
Page 1 of 4
Adjustment Bolt Location