Flowserve PT Series Limitorque User Manual
Page 39
![background image](https://www.manualsdir.com/files/784831/content/doc039.png)
39
Limitorque PT Series Worm Gear Operator FCD LMENIM2001-00 – 01/10
flowserve.com
Table 4.8 – Parts List – Spur Gear Attachment – PT65, 120, 150
Piece #
Description
1
SGA Housing
2
SGA Cover
3
Input Pinion
4
Intermediate Gears
5
Output Gear
6
Needle Roller Bearing
7
Radial Ball Bearing
8
Dowel Pin
9
Socket Head Cap Screw
10
Lip Seal
11
Pipe Plug
12
Key
13
SGA Housing Gasket
4.11 Spur Gear Attachments - PT250, 500, 1000
Refer to Figure 4.21, 4.22 and Table 4.9
1. Remove the hex head cap screws from the Unit Adapter (pc# 43) and remove the Unit Adapter from the SGA
(Spur Gear Attachment) Cover (pc# 38).
2. Remove all traces of the SGA Adapter Gasket (pc# 42).
3. Remove the SGA Pinion (pc# 35)
4. Remove the Ball Bearing (pc# 29) from the SGA Cover.
5. Remove the hex head cap screws that attach the SGA Cover to the SGA Housing (pc# 26) and remove
the SGA Cover.
6. Remove the Spur Gear (pc# 33) from the Drive Pinion (pc# 31)
7. Remove the Drive Pinion
8. Remove the SGA Cover Gasket (pc# 36) from the SGA Cover surface
9. Remove the Ball Bearing (pc# 28) from the Worm Shaft (pc# 2)
10. Remove the SGA Input Gear (pc# 27) from the Worm Shaft
11. Remove the SGA Housing (pc# 26) from the PT Housing (pc#1)
12. If disassembly of the PT is required, please see section 4.6