Specifications – Drolet Nova 820 User Manual
Page 5
ELATION Fireplace Insert
5
SPECIFICATIONS
Dimensions:
height:
20”
(508
mm)
width:
front: 28” (711 mm) rear: 16” (406 mm)
depth:
14
3/4”
(375
mm)
Surround
dimensions:
Small
Large
width:
40”
(1016
mm) 44”
(1118
mm)
height:
25 ½” (648 mm)
27 ½” (699 mm)
Glass:
5mm 28" (711 mm) x 11 ¼” (286 mm) 1400
° F clear ceramic
Fuel:
Natural Gas
Propane
Maximum input :
25,000 (7.3) 25,000 (7.3)
Btu/h (kWh)
Minimum input:
17,000 (5.0) 19,000 (5.6)
Btu/h (kWh)
Manifold pressure :
3.5/1.8 (0.9/0.5) 10.5/7.0 (2.6/1.8)
in w.c. (kPa)
Min. inlet pressure :
5 (1.3)
11 (2.8)
in w.c. (kPa)
Max. inlet pressure :
8 (1.8)
14 (3.5)
in w.c. (kPa)
Orifice size/Altitude:
42 dms 0-4500 ft
53 dms 0-4500 ft
Output capacity (Blower off): 18,500 (5.4)
18,500 (5.4)
Btu/h (kWh)
Output capacity (Blower on): 20,000 (5.9)
20,000 (5.9)
Btu/h (kWh)
Efficiency
(Blower
off):
73.5%
73.5%
Efficiency
(Blower
on):
80.6%
80.6%
Vent:
4” "B-vent", "L-vent" or certified flex liner
Valve:
SIT model Nova 820 adjustable millivolt valve
Blower :
variable speed, 130 CFM (3.68 m
3
/min)
Thermo-switch: 110
° F (43° C) “ON”, 90° F (32° C) “OFF” bi-metal type.