GLASS FRONT REMOVAL, CLEANING AND INSTALLATION

Removal:

• Let the insert cool down for at least one hour.
• Open the top and bottom louvres to reveal the retaining brackets.
• Remove the two (2) screws holding the top bracket and remove the bracket still

holding the glass in place.

• Lift out glass. (Do not let glass fall forward!)

CAUTION : Do not operate your insert without a glass front or with a broken glass.

Cleaning:

• Only clean the glass when cold.
• Clean with liquid type cleaners or soap and water; do not use abrasive cleaners,

which can scratch the glass.


Installation:

• Place the glass front assembly back in position. Align the top bracket with the holes for the

screws.

• Install the two (2) screws.