Align terminal box, Remove terminal box, Align terminal box remove terminal box – Flowserve NRGS15-1 User Manual
Page 17: Installation

17
– continu ed –
Align terminal box
Align the terminal box such that the LEDs
,
,
,
,
can be seen by the operator.
1.
Undo the housing screws
and remove the housing lid
.
2.
Use open-end spanner A. F. 18 (19) mm to loosen the fixing nut
and turn the ter-
minal box into the desired direction (cable gland).
3.
Re-tighten the fixing nut
with a torque of 25 Nm.
4.
Replace the housing lid
and tighten the housing screws
firmly.
If necessary you can take off the terminal box in order to align the electrode part. The ter-
minal box must be re-installed after alignment.
Remove terminal box
1.
Undo the housing screws
and remove the housing lid
.
2.
Unplug the electrode wires from terminal lugs for electrode wires, functional earth
and mark them.
3.
Use open-end spanner A. F. 18 (19) mm to unscrew the fixing nut
. Pull electrode
wires through fixing nut
.
4.
Remove terminal box. Run all electrode wires through the hole for the fixing screw
(see Fig. 5).
5.
Remove the gasket
between the electrode part and the housing.
1
2
3
4
5
G
F
M
M
F
G
G
F
N
M
M
A