Technical data - akh2 with manual actuator, Technical manual – Flowserve AKH2 IOM Atomac Lined Ball Valve IOM User Manual
Page 14
AKH2 -
atomac ball valve - full port
Ahaus GmbH
von-Braun-Straße 19a
D-48683 Ahaus
Postfach 1162 D-48661 Ahaus
Telefon: +49(0) 2561-686-100
Fax: +49(0) 2561-686-200
Register:
2
Page:
14
Date:
12.1995
Revision:
02.2009
Technical Manual
Technical Data - AKH2 with manual actuator
* with standard hand wheel
DIN EN ISO 5211
DIN EN ISO 5211
Type
gear transmission ratio
Nm
torque in lbs
weight in kg
Q - 400 S
44 : 1
400
3540
3,87
Q - 800 S
40 : 1
800
7081
7,68
Q - 2000 S
48 : 1
2000
17701
16,3
DIN EN ISO 5211
DIN EN ISO 5211
DIN
ANSI
TYP*
A
B
C
D
ØE
F
ØG
K
100
4“
mm
Q 400 S
296,8
142
80
34
200
213
12
52,5
inch
11,69
5,59
3,15
1,34
7,87
8,39
0,47
2,07
150
6“
mm
Q 800 S
374,5
204
80
42,5
300
283
15
68,8
inch
14,74
8,03
3,15
1,67
11,81
11,14
0,59
2,71
200/150 8“/6“
mm
Q 800 S
374,5
204
80
42,5
300
283
15
68,8
inch
14,74
8,03
3,15
1,67
11,81
11,14
0,59
2,71
200
8“
mm
Q 800 S
426,5
256
80
42,5
300
283
15
68,8
inch
16,79
10,08
3,15
1,67
11,81
11,14
0,59
2,71
250
10“
mm
Q 2000 S
521
301
120
50
400
314
20
96,5
inch
20,51
11,85
4,72
1,97
15,75
12,36
0,79
3,8
300
12“
mm
Q 2000 S
563
343
120
50
600
349
20
96,5
inch
22,17
13,5
4,72
1,97
23,62
13,74
0,79
3,8
-
14“
mm
Q2000 S
600
373
120
50
600
349
20
96,5
inch
23,62
14,69
4,72
1,97
23,62
13,74
0,79
3,8