Flowserve Mach 1 User Manual
Page 2
2
®
User Instructions Mach 1 High Performance Plug Valve - DVENIM0300-01 - 03.13
FLANGED:
Installation of Flowserve flanged valves is best accomplished by
locating valves in pipeline flanges, assuring all corrosion and foreign
materials are removed from pipe flanges and then center gaskets
with the valve flanges. Fasteners or taper pins should be used to
align holes and locate gaskets. Fasteners should be tightened to the
corresponding valve and fastener size.
SECTION I
INSTALLATION INSTRUCTIONS - FLANGED MACh 1, CLASS 150, 300 AND 600
TABLE I
Temperature Limitations
TABLE OF CONTENTS
SECTION TITLE PAGE
I INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
II
OPERATING/MAINTENANCE INSTRUCTIONS FOR MACH 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
III
VALVE DISASSEMBLY - MACH 1
RECOMMENDED PRECAUTIONARY MEASURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
DISASSEMBLY STEPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
IV
PRESSURE CONTAINING FASTENERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
V
A. VALVE ASSEMBLY 1"-6" MACH 1 WITH PORT SEALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
B. VALVE ASSEMBLY 1"-6" MACH 1 WITH SLEEVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
VI
ASSEMBLY SPECIFICATIONS - FIRESEAL VALVES 1"-6" MACH 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Type
Material Description
Max Service
Temperature
PFA
R Seat (full, no insert)
400°F (204°C)
S Seat (full, insert)
525°F (274°C)
P Seat (partial, insert)
525°F (274°C)
Tefzel
300°F (149°C)
VMPE
200°F (93°C)
DANGER: indicates that death, severe personal injury
and/or substantial property damage will occur if proper
precautions are not taken.
WARNING: indicates that death, severe personal injury
and/or substantial property damage can occur if proper
precautions are not taken.
CAUTION: indicates that minor personal injury and/or
property damage can occur if proper precautions are
not taken.
NOTE: indicates and provides additional technical infor-
mation, which may not be very obvious even to quali-
fied personnel. Compliance with other, not particularly
emphasised notes, with regard to transport, assembly,
operation and maintenance and with regard to technical
documentation (e.g. in the operating instruction, pro-
duct documentation or on the product itself) is essen-
tial, in order to avoid faults, which in themselves might
directly or indirectly cause severe personal injury or
property damage.
STOP!