Sl-5200 buffer fluid system recommendations – Flowserve SL-5000 Seals User Manual
Page 5
![background image](https://www.manualsdir.com/files/784364/content/doc005.png)
5
SL-5200 Buffer Fluid System Recommendations
Figure 2
RPM
1800
1500
1200
900
32 to 50 mm
(1.25 to
2.000 inch)
53 to 76 mm
(2.125 to
3.000 inch)
80 to 102 mm
(3.125 to
4.000 inch)
105 to 127 mm
(4.125 to
5.000 inch)
130 to 152 mm
(5.125 to
6.000 inch)
External Flush or
Consult Flowserve
Thermal Convection
System with Plain
Supply Tank
Consult
Flowserve
Consult
Flowserve
Circulating Feature and Supply
Tank with Cooling Coil
Shaft or Seal Size
Notes
1. Recommendations are for use with a water buffer fluid only.
2. These recommendations apply to products having a maximum
temperature of 71°C (160°F).
3. Systems can be applied at the seals maximum pressure limit
according to PV curve 2D-255497.
4. In most cases other systems can be successfully applied.
Consult Flowserve for other options.