Operational Recommendations
3 SL-5000
3.1 Do not start the equipment dry.	Never	start	up	the	equipment	
without properly venting the pump of air.
3.2 If the seal runs hot, check for proper seal setting, seal housing
dimensions, and check the flush lines for obstructions. Do not
allow the equipment to run for any extended time if the seal gets
hot or squeals.
4 SL-5200
Figure	2	contains	guidelines	for	buffer	fluid	systems	which	can	be		
used with the SL-5200 double seal. Figure 3 is a suggested piping
arrangement for the SL-5200 with circulating feature and supply tank
with cooling coil. For other sealing liquid systems using Dura Circulators,
external flushing or thermal convection, refer to the assembly drawing or
consult	Flowserve,	Flow	Solutions	for	instructions.
4.1 Always start up the sealing liquid supply before starting 
equipment. Be sure that the sealing liquid pressure is greater
than the maximum pressure of the process fluid acting on the
seal chamber.
4.2 Seal liquid pressure must not exceed the pressure velocity rating
of the seal design and materials of construction.
4.3	 Be	sure	cooling	water	to	supply	tank	or	circulator	is	on.
4.4 Never start up equipment dry.	Properly	vent	all	air.
4.5	 If	the	seal	runs	hot	or	squeals,	check	the	seal	liquid	flow	between	
the seals and check the seal housing dimensions to insure that the
seal is not over-compressed.
For special problems encountered during installation, contact your