4 inspection and reconditioning – Flowserve ISC2 Single Pusher Repair User Manual
Page 3
3
Seal parts that are reconditionable
• Gland assembly [11]
• Sleeve assembly [1]
• Sleeve collar [58]
4 Inspection and Reconditioning
There are certain critical areas of each part where special attention should be
paid to the condition. If any of the listed areas show signs of wear, corrosion,
or other defects that cannot be removed without affecting the dimensional size
of the surfaces by more than 0.001 - 0.002 inch (0.025 - 0.05 mm), then the
respective part should be replaced. If grit blasting is performed, polish the O-ring
surfaces to achieve the required surface finish (see critical area listings for finish
requirements). If any parts require machining to correct damage, please contact
your Flowserve representative for dimensional requirements, or for any other
questions regarding repair.
4.1 Gland assembly [11] see Figures 2 and 3.
A Dynamic O-ring surface - Inspect for wear,
fretting, nicks, scratches or corrosion.
Required surface finish: 32 RMS
B Gasket surface - Remove the old gasket and
clean the gasket surface. Inspect for nicks,
scratches or corrosion.
C Pipe taps and lifting holes - Inspect for
damaged threads or corrosion. Re-tap as
necessary.
D Anti-rotation pins - Inspect for wear or
corrosion. Replace as necessary.
4.2 Sleeve assembly [1] see Figures 4 and 5.
A O-ring surfaces - Inspect for wear, nicks,
scratches, or corrosion. Required surface
finish: 63 RMS.
B Drive flats or drive pin - Inspect for wear or
corrosion. Replace pin as necessary.
C Drive end roundness - No greater than
0.001 inch (0.025 mm) TIR (Total Indicated
Reading) under the bushing.
D Inspect ID of sleeve at weld point for
corrosion.
Figure 2
C
D
B
A
B
A
Figure 3
C
D