Calibration, Floscan instrument company, inc – Floscan TwinScan Tachometer User Manual

Page 13

background image



6/16/2006

1000-207-00

CALIBRATION

TwinScan 3” Instrument – Tachometer (LCD)
Diesel Engines

Back of Instrument

Dial Lamp

0

0

Wires

Calibration Knobs

Black Switch

Red Switch


The TwinScan 3” Tachometer is unique in that it can be calibrated for both gasoline and
diesel systems. On the back of the TwinScan 3” Tachometer Instrument, the RED
switch is used for fine calibration. The BLACK switch is used for coarse calibration.
You will use a combination of both switches for proper calibration.

DIESEL SYSTEM CALIBRATION


Diesel systems have three options for tachometer pick-up styles, Mechanical AC Generator, Magnetic Pick-up, and Alternator.
Table 1
will be used to calibrate any style of tachometer pickup you may have. Please read the section pertaining to your specific
tachometer pick-up style for instructions on calibrating the tachometer.

I.

MECHANICAL AC GENERATOR

1. Determine the number of pole pairs of your generator. Some examples are:

Century Brass 8

Stewart Warner 8

Hewitt 8

Synchrostart 30

VDO 4

Motorola 8

2. Determine the ratio of the number of revolutions of the crankshaft drive to the number of revolutions of the tachometer. For

most engines, the ratio is 0.5. If you are not sure of your tachometer drive ratio, you can either check with your local engine
dealer or you can adjust the RED and BLACK switches until you get a reading of 500-800 RPM at a normal idle with the
engine at or near normal operating temperature.

3. Calculate the proper switch setting:

Tachometer drive ratio x number of generator pole pairs = number used to determine RED and BLACK switch settings
from Table 1.

Example: Installation - Caterpillar 3208 with an 8 pole pair generator.

Crankshaft revolution to tachometer drive = 0.5 ratio.
Generator = 8 pole pair.
0.5 (ratio) x 8 (pole pair) = 4 (generator produces 4 pulses per revolution).


The switch setting selection would be as follows:

50 RPM synchronized resolution - RED switch = 3

BLACK switch = 1

20 RPM synchronized resolution - RED switch = 3

BLACK switch = 9


II. MAGNETIC

PICK-UP


This instrument must be calibrated at the time of installation to your specific engine in the following manner:

1. Determine the number of pulses of the magnetic pick-up per crankshaft revolution. If you are not sure what this is, contact

you local engine dealer and they can provide this information.
Pulses = (number of teeth on gear) x (number of revolutions of gear per crank shaft revolution).
The table steps allow setting to be within +/- 1% to 2% of the actual pulse count. As this applies to both engines, the
synchronizing accuracy is not affected.


2. Locate the number of pulses per crankshaft revolution in Table 1. Select the number closest to your actual pulses per

crankshaft revolution.
Example: Pulses per crank shaft revolution = 160. From Table 1:

50 RPM synchronized resolution - RED switch = B

BLACK switch = 6

20 RPM synchronized resolution - RED switch = B

BLACK switch = E