Introduction
Complementing the flexibility of the FiberPlex ‘TD Series’ of fiber optic modules, the TDP provides front of rack
connection, mounting, power, and cable management for up to 6 front facing TD modules in a compact and
rugged aluminum 1U rack. Each of the 16 channels of the modular TDP front panel can accommodate any
Neutrik™ D Series connector, LC and ST barrel connectors, DB9 connectors, etc. The unused positions are
simply fitted with a blank panel. The integrated key‐hole mounting holes on the bottom of the TD units lock
securely on mating studs while a rear retention bar holds them securely in place. A 6 position power wiring
harness and included power adapter provide, not just 9 VDC power, but a positive earth ground to the
modules via 3 position Phoenix™ locking power connectors. Managing all that cabling and fiber can
sometimes be quite a chore, the TDP allows a simple solution to put maximum capacity and flexibility into a
single 1U space.
Key Features
Provides mounting and power for up to 6 single wide or 3 double wide TD Series
modules
Perfect for front of rack connections
Accommodates up to 16 connector positions
Plates available for standard Neutrik™ D Series connectors, LC and ST barrels, DE‐9, etc
Selected connectors included
Reconfigure in minutes
Securely seats modules with positive retention bar
Power adapter and wiring harness included
Convenient cable tray for clean installation
Grounding stud for positive earth ground
Reinforced rack ears
Getting Started
Initial Inspection
Immediately upon receipt, inspect the shipping container for damage. The container should be retained until
the shipment has been checked for completeness and the equipment has been checked mechanically and
electrically. If the shipment is incomplete, if there is mechanical damage, or if the unit fails to operate notify
FiberPlex and make the shipping materials available for the carrier's inspection.
Chassis Mounting
Mount the empty chassis using fasteners appropriate to your standard 19” rack enclosure. All four (4)
mounting points MUST be utilized. Ensure that there exists adequate clearance for ventilation. The chassis
should be located in an environment where an ambient temperature between 0° and 50° C can be maintained.
Power Requirements
Any combination of 6 FiberPlex TD Series Modules can be mounted in a TDP. Each TD module can draw as
much as 500 mA at 9VDC, so with the maximum 6 modules installed the maximum power requirement for a
power adapter is 3A at 9V or 18 Watts. Power is supplied to the individual modules through a pre‐wired Power
Harness that connects to the modules using a 3 pin Phoenix™ connector. Two pins supply the 9 VDC and the
third pin connects a positive earth ground to a ground lug on the rear of the TDP. For best performance it is
recommended to connect the ground lug to a known good earth ground. DC power is supplied to the Power
Harness through the included power adapter connected to the rear circular connector.