Controlling the panel
We recommend controlling this panel using an external room thermostat with a switch.
The room thermostat maintains the set air temperature in the room.
Furthermore, the panel is fitted with a limit thermostat which ensures its safe operation.
Uninstalling the panel
Disconnect the panel from the mains using a two-pole switch before uninstalling it. Lift the panel upwards vertically and sideways in such a
way that it is released from the screws. Furthermore, the supply cable must be disconnected from the box on the wall.
Technical specifications
The panel can be installed on bases of flammability class C or D.
Type
Dimensions (mm)
(LxWxH)
Weight
(kg)
Output
(W)
Current
(A)
Voltage
(V) AC
Protection
class
Coverage
Ecosun 750 IKP
1192x592x30
11
750
3,3
230 V
I
IP 54
Fig. 5
Mounting frame
W A
(mm)
B
(mm)
750 935 360
W A
(mm)
B
(mm)
750 935 280