Installation instructions

Installation, electrical connection and the first commissioning is permitted to be

performed by a worker with relevant qualifications. The panels are intended for

mounting on a wall or ceiling , or – if legs are purchased and fitted - as free-

standing heaters

.

The producer must be consulted before any other form of

installation is attempted.

Installation on the ceiling

Position the mounting frame in the location where the panel is to be placed,
using a pen, mark holes according to the holes on the frame.

Drill the holes, insert the wall anchors and attach the mounting frame with the
screws.

Always hang the panel by all four mounting slots

Slide the panel into the mounting frame.

Installation on the wall

Mark the holes according to the table, drill out the holes, insert the dowels
and drive the screw in to protrude approx. 5 mm. (Fig. 4)

Always hang the panel by all four mounting slots.

Put the panel on the screws.

Installation in an open area – free-standing

(fig. 4)

Slide the panel onto the leg brackets and place it at the required location.

Clearance distances

The distance between the bottom edge of the appliance and the floor mustn’t be

less than 50 mm; 150 mm is recommended. The clearance distance on the side

(e.g. from furniture) must be at least 100 mm, and 100 mm is the minimum in

the upward direction (see Fig. 2).

In bathrooms, the panel must be installed in accordance with the HD 60364-7-

701:2007 standard and is permitted to be located in accordance with Fig 1.

Electric installation

The panel is equipped with a three-wire cable with a plug for connection to an

electrical socket. Power cable length: 1.9m.

Removal of the plug and shortening of the supply lead will not result in loss of
warranty

.

The power supply cable is connected to a box on the wall, see Fig 3.

The panel must not be placed directly under an electric socket.

The supply cable must be fitted with a device for disconnection from the mains

in which the distance between the disconnected contacts is at least 3.5 m for all

poles.

The power cable cannot be exchanged. If the power cable is damaged, the

appliance should be discarded.

Fig.4