Electric installation

The panel is fitted with a two-conductor cable for 1/N 230 V / Hz with a plug for connection into a socket

.

Removal of the plug and shortening of the supply lead will not result in loss of warranty.
Colour marking of the conductors:
Phase – brown
Central (live) conductor – blue
The power supply cable is connected to a box on the wall, see Fig 3.
The panel must not be placed directly under an electric socket.
The supply cable must be fitted with a device for disconnection from the mains in which the distance between the disconnected contacts is
at least 3.5 m for all poles.
If the supply cable of this appliance is damaged, it has to be replaced by the producer or a service technician.


Controlling the panel

We recommend controlling this panel using an external room thermostat with a switch.
The room thermostat maintains the set air temperature in the room.
Furthermore, the panel is fitted with a limit thermostat which ensures its safe operation.


Uninstalling the panel

Disconnect the panel from the mains using a two-pole switch before uninstalling it. Lift the panel upwards vertically and sideways in such a
way that it is released from the screws. Furthermore, the supply cable must be disconnected from the box on the wall.



Technical specifications

* mirror
The panel can be installed on bases of flammability class C or D.


Type

Dimensions (mm)

(LxWxH)

Weight

(kg)

Output

(W)

Current

(A)

Voltage

(V) AC

Protection

class

Coverage

G 300

600x600x40

7/10.2*

300

1,3

230 V

II

IP 44

G 600

1200x600x40

14/19*

600

2,6

G 850

1200x800x40

18,6

850

3,7