Electric installation, Controlling the panel, Uninstalling the panel – Fenix ECOSUN G User Manual
Page 9: Technical specifications

9
Electric installation
The panel is fitted with a two-conductor cable for 1/N 230 V / Hz with a plug for connection into a socket
.
Removal of the plug and shortening of the supply lead will not result in loss of warranty. 
Colour marking of the conductors: 
Phase – brown 
Central (live) conductor – blue 
The power supply cable is connected to a box on the wall, see Fig 3. 
The panel must not be placed directly under an electric socket. 
The supply cable must be fitted with a device for disconnection from the mains in which the distance between the disconnected contacts is 
at least 3.5 m for all poles. 
If the supply cable of this appliance is damaged, it has to be replaced by the producer or a service technician. 
 
 
Controlling the panel
We recommend controlling this panel using an external room thermostat with a switch. 
The room thermostat maintains the set air temperature in the room. 
Furthermore, the panel is fitted with a limit thermostat which ensures its safe operation. 
 
 
Uninstalling the panel
Disconnect the panel from the mains using a two-pole switch before uninstalling it. Lift the panel upwards vertically and sideways in such a 
way that it is released from the screws. Furthermore, the supply cable must be disconnected from the box on the wall. 
 
 
 
Technical specifications
* mirror 
The panel can be installed on bases of flammability class C or D. 
 
 
Type
Dimensions (mm)
(LxWxH)
Weight
(kg)
Output
(W)
Current
(A)
Voltage
(V) AC
Protection
class
Coverage
G 300
600x600x40
7/10.2*
300
1,3
230 V
II
IP 44
G 600
1200x600x40
14/19*
600
2,6
G 850
1200x800x40
18,6
850
3,7