Electric installation, Controlling the panel, Uninstalling the panel – Fenix ECOSUN G User Manual
Page 9: Technical specifications
9
Electric installation
The panel is fitted with a two-conductor cable for 1/N 230 V / Hz with a plug for connection into a socket
.
Removal of the plug and shortening of the supply lead will not result in loss of warranty.
Colour marking of the conductors:
Phase – brown
Central (live) conductor – blue
The power supply cable is connected to a box on the wall, see Fig 3.
The panel must not be placed directly under an electric socket.
The supply cable must be fitted with a device for disconnection from the mains in which the distance between the disconnected contacts is
at least 3.5 m for all poles.
If the supply cable of this appliance is damaged, it has to be replaced by the producer or a service technician.
Controlling the panel
We recommend controlling this panel using an external room thermostat with a switch.
The room thermostat maintains the set air temperature in the room.
Furthermore, the panel is fitted with a limit thermostat which ensures its safe operation.
Uninstalling the panel
Disconnect the panel from the mains using a two-pole switch before uninstalling it. Lift the panel upwards vertically and sideways in such a
way that it is released from the screws. Furthermore, the supply cable must be disconnected from the box on the wall.
Technical specifications
* mirror
The panel can be installed on bases of flammability class C or D.
Type
Dimensions (mm)
(LxWxH)
Weight
(kg)
Output
(W)
Current
(A)
Voltage
(V) AC
Protection
class
Coverage
G 300
600x600x40
7/10.2*
300
1,3
230 V
II
IP 44
G 600
1200x600x40
14/19*
600
2,6
G 850
1200x800x40
18,6
850
3,7