Installation instructions, Installation on the ceiling, Installation on the wall – Fenix ECOSUN E User Manual
Page 6: Clearance distances, Electric installation, Controlling the panel, Uninstalling the panel

6
Installation instructions
Installation, electrical connection and the first commissioning is permitted to
be performed by a worker with relevant qualifications. The panels are in-
tended for mounting on a wall or ceiling. The producer must be consulted
before any other form of installation is attempted.
Installation on the ceiling
•
Position the mounting frame in the location where the panel is to be
placed, using a pen, mark holes according to the holes on the frame.
•
Drill the holes, insert the wall anchors and attach the mounting frame with
the screws.
•
Always hang the panel by all four mounting slots
•
Slide the panel into the mounting frame.
Installation on the wall
•
Mark the holes according to the table, drill out the holes, insert the dowels
and drive the screw in to protrude approx. 5 mm. (Fig. 4)
•
Always hang the panel by all four mounting slots.
•
Put the panel on the screws.
Clearance distances
The distance between the bottom edge of the appliance and the floor mustn’t
be less than 50 mm; 150 mm is recommended. The clearance distance on
the side (e.g. from furniture) must be at least 100 mm, and 100 mm is the
minimum in the upward direction (see Fig. 2).
In bathrooms, the panel must be installed in accordance with the HD 60364-7
-701:2007 standard and is permitted to be located in accordance with Fig 1.
The panel is a class II appliance, with IP 44 coverage. The panel must not be
placed directly under an electric socket.
Electric installation
The panel is fitted with a two- conductor cable for 1/N 230 V / 50 Hz with a
plug for connection into a socket
.
Removal of the plug and shortening of the supply lead will not result in loss of
warranty
.
Colour marking of the conductors:
Phase
–
brown
Central (live) conductor – blue
The power supply cable is connected to a box on the wall, see Fig 3.
The panel must not be placed directly under an electric socket.
The supply cable must be fitted with a device for disconnection from the mains in which the distance between the disconnected contacts is
at least 3.5 m for all poles. If the supply cable of this appliance is damaged, it has to be replaced by the producer or a service technician.
Controlling the panel
We recommend controlling this panel using an external room thermostat with a switch.
The room thermostat maintains the set air temperature in the room.
Furthermore, the panel is fitted with a limit thermostat which ensures its safe operation.
Uninstalling the panel
Disconnect the panel from the mains using a two-pole switch before uninstalling it. Lift the panel upwards vertically and sideways in such a
way that it is released from the screws. Furthermore, the supply cable must be disconnected from the box on the wall.