beautypg.com

Service call check, Specifications – Dacor DCM24 User Manual

Page 28

background image

26

A35411,DCM24S/B/R

SERVICE CALL CHECK

Please check the following before calling for service:

1. Place one cup of water in a glass measuring cup in the oven and close the door securely.

Operate the oven for two minutes at HIGH 100%.

A. Does the oven light come on?

YES _______

NO _______

B. Does the cooling fan work?

YES _______

NO _______

(Put your hand over the rear ventilating openings.)

C. Does the turntable rotate?

YES _______

NO _______

It is normal for the turntable to turn in either direction.

D. Is the water in the oven hot?

YES _______

NO _______

2. Remove water from the oven and operate the oven for 5 minutes at CONV 450°F.

A. Do CONV and COOK indicators light?

YES _______

NO _______

B. After the oven shuts off, is inside of the oven hot?

YES _______

NO _______

If “NO” is the answer to any of the above questions, please check electrical outlet, fuse and/or circuit
breaker.
If both are functioning properly, CONTACT YOUR NEAREST AUTHORIZED DACOR SERVICER. A
microwave oven should never be serviced by a “do-it-yourself” repair person.

NOTE: If time appearing in the display is counting down very rapidly, check Demonstration Mode on page 24

and cancel.

SPECIFICATIONS

AC Line Voltage:

Single phase 120V, 60Hz, AC only

AC Power Required:

1.55 kW 13.0A (Microwave)
1.55 kW 13.0A (Convection)

Output Power:

Microwave

900W

*

(IEC Test Procedure)

Convection Heater

1450W

Frequency:

2450 MHz

Outside Dimensions:

24

5

/

8

”(W) x 14

7

/

8

”(H) x 19”(D)

Cavity Dimensions:

16

1

/

8

”(W) x 9

5

/

8

”(H) x 16

1

/

8

”(D)

Oven Capacity:

1.5 cft

Cooking Uniformity:

Turntable system

Weight:

Approx. 60 lbs.

*

the International Electrotechnical Commission’s standardized method for measuring output wattage. This
test method is widely recognized.

In compliance with standards set by:

FCC

Federal Communications Commission Authorized.

DHHS

Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I,
Subchapter J.

This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.