beautypg.com

Low pressure auto reset – Dimplex Shower User Manual

Page 2

background image

SECTION 1

Unpacking and important notices

Contents

1 x Shower Unit

1 x Showerhead

1 x Flexible Hose

1 x Slider Rail Tube

1 x Slider Rail Brackets

1 x Height adjuster

1 x Screw pack

1 x Soap dish

1 x Showerhead key

IMPORTANT NOTICES

PLEASE READ BEFORE ATTEMPTING

TO INSTALL THE SHOWER UNIT

1) The shower unit must be installed by a

suitably qualified person and conform

to IEE Regulations and National Water

Council Bylaws.

2) The shower must only be connected

to a 15mm mains cold water supply.

Do not connect the unit to the cold

water supply of a header tank.

3) The minimum recommended running

water pressure to which the shower

heater may be connected is 15lb/sq in

(1bar); running pressure of 8 litres/minute;

maximum static pressure recommended

150lb/sq in (10 bar).

4) The shower unit must not be fitted

where it may be exposed to frost, for

example in an outdoor shower area. The

shower must not be used if suspected of

being frozen. Please note: Frost damage

is not covered by the guarantee.

5) Do not use Plumbers jointing compound.

Use of plumbers jointing compounds

invalidates the guarantee.

Complete all plumbing connections

before making any electrical connections.

The outlet of the shower unit must only be

connected to the hose and showerhead

supplied with the unit. Use of other

components will invalidate the warranty.

Always switch off at the isolating switch

when the shower is not in use.

To comply with National Water Council

bylaws a double check valve must be

fitted where it is possible that the shower-

head may come into contact with used

water e.g. in the shower tray or bath.

Do not operate power tools in a wet envi-

ronment. It is recommended that any power

tools operated in the bath or shower area are

supplied via a Residual Current Device (RCD).

WARNING! THIS APPLIANCE MUST BE EARTHED.

This shower is for connection to a

230V-240V/50Hz mains electricity supply.

SECTION 2

Installation

Typical instantaneous electric shower

installation

DIMENSIONS

UNPACKING AND IMPORTANT NOTICES / INSTALLATION

HIGH

LOW

COLD

LOW

PRESSURE

AUTO
RESET

TEMPERATURE

STOP

610mm

218mm

339mm

Double pole heater switch wall mounted in
accordance with local authority regulations

Seperate permanently
connected supply
from consumer unit

Isolating
stop tap

Dimplex electric

water heater

Cold

water
mains

supply

2

3

Dimp13292-Shower inst aX4 5/5/04 2:08 pm Page 3