INSTALL DISCHARGE TUBE
Half of the mounting clamp is already attached to
the discharge tube.
1. Slide the discharge tube over the mounting
flange on the blower housing and tighten the
bolts to secure it.
2. Attach the second half of the clamp to the tube
and flange with 3/8 x 1-1/4" bolts and nuts.
3. Rotate the tube 360 degrees and lock it
in place with the handle to make sure it is
mounted correctly.
COMPLETED PULLEY INSTALLATION
10. Slide the pulley onto the rotor shaft. Mount the outside belt on the 5.2" pulley and connect it to the 5" blower pulley.
Align the small pulley to the 5" blower pulley with a straightedge. Tighten the 5.2" pulley securely.
11. Attach the front belt guide to the top rotor shaft bolt. Replace nut and tighten securely.
12. Insert the rear belt guide into the hole next to the blower pulleys. Adjust the guide for a 3/16" clearance from the top
surface of the belt and tighten with nut.
FRONT
VIEW
TOP