Owner’s manual, Battery, Extension cords – Desa Rgh3000 EN User Manual

Page 9: Generator grounding, Continued

background image

9

104960

OWNER’S MANUAL

Ampere

AWG for Length of

Load

Cord in Feet

50'

100'

150'

2

18

18

18

3

18

18

18

4

16

16

16

5

16

16

16

6

16

16

14

8

16

14

12

10

16

14

12

12

14

14

12

14

14

12

10

16

12

12

10

20

10

10

8

FUEL

F

FUEL

F

TO STARTER
SOLENOID

TO ENGINE
BLOCK

120

ON

LY

120

240

V

EN

M

000

000

05

HO

UR

S

1

/10

FULL POWER

Figure 12 - Connecting Positive and
Negative Cables to Battery
(Model RGH7500IE Shown)

BATTERY

Continued

Figure 11 - Battery Hold-Down System
(Model RGH11000IE Shown)

Battery
Mounting
Bracket

FUEL

F

Figure 13 - Connecting Positive and
Negative Cables to Battery
(Model RGH11000IE Shown)

TO
STARTER
SOLENOID

TO
ENGINE
BLOCK

Battery

Hook
Bolt

Nut

Grounding generator helps prevent electric
shock from a ground fault condition. Locate
ground lug on end of generator housing (see
Figure 12). Attach a #10 stranded-copper
ground wire to ground lug. Drive grounding
point into ground. Grounding point can be a
stake, grounding rod, or pipe. Grounding
point should be copper or brass. Attach
ground wire to grounding point. You must
supply the ground wire and grounding point.
These do not come with generator. Follow
the National Electrical Code and all state
and local codes. Consult your power com-
pany or a licensed electrician.

Ground Lug

Ground Wire

Alternator

Copper or Brass
Grounding Point

Figure 14 - Grounding Generator
(Model RGH5500 Shown)

EXTENSION
CORDS

Only use grounded extension cords. Be sure
to use extension cord with proper wire gauge
size. See chart below.

Recommended Minimum Wire
Gauges (AWG) for Extension
Cords

GENERATOR
GROUNDING

WARNING: You must prop-

erly earth-ground generator be-
fore starting. This will help guard
against deadly electric shock.
Only use grounded plugs with
generator. Only use grounded ex-
tension cords. Only use three-
wire or double-insulated power
tools.

WARNING: For a grounding

point, do not use metal pipe be-
ing used to carry combustible
materials or gases.