beautypg.com

Owner’s manual, Operation, General information – Desa Rgh3000 EN User Manual

Page 11: Using receptacle, Power cord and plug requirements, Figure 16 - cord and plug configurations continued

background image

11

104960

OWNER’S MANUAL

RESET

240 VOLTS

RESET

RESET

RESET

RE

SE

T

TE

ST

120

VO

LTS

RESET

RESET

ENM

00000005

HO

UR

S 1

/10

120

ON

LY

120

240

V

OPERATION

GENERAL INFORMATION

This generator is not large enough to power
your entire home. Do not connect generator
to any existing electrical circuits. Plug items
directly into generator receptacles. Do not
exceed amperage rating of receptacles. Only
use grounded cords.

DANGER: Use only in well-

vented areas. Make sure area has
plenty of free-moving, fresh, out-
side air. Never run generator in
an enclosed or confined area.
Never run generator inside occu-
pied building. Engine exhaust
contains poisonous carbon mon-
oxide gas. Overexposure will
cause loss of consciousness and
will lead to death.

DANGER: Never connect gen-

erator to any existing electrical
circuits. The generator output will
back-feed into the utility power
line. This may electrocute a power
company line repair person. Also,
if generator is powering electri-
cal circuits, the chance of an elec-
trical fire exists.

Note:

We supply the engine owner’s manual

with generator. Refer to that manual for
questions concerning engine operation.

USING RECEPTACLE

Note:

Do not exceed amperage rating of

receptacles. Exceeding rating will trip re-
ceptacle circuit breaker.

Use receptacles properly. Improper use could
damage generator. Use only grounded ex-
tension cords. Power only grounded or
double-insulated items. Do not overload
receptacles. All generators (except models
RGH3000 and RGH3000PR) have the fol-
lowing receptacles (see Figure 15):

• 120V, 15-amp GFCI duplex receptacle

• 120V, 30-amp twist-lock receptacle

• 120/240V, 20 or 30-amp twist-lock

receptacle

• 120V, 15-amp duplex receptacle

Figure 15 - Receptacle Locations

120V, 15-Amp GFCI Duplex

120/240V, 20 or 30-
Amp Twist-Lock

120V, 30-Amp
Twist-Lock

120V, 15-Amp Duplex

120/240V, 50-Amp

(Model RGH11000IE only)

Model RGH11000IE also has a 120/240V,
50-amp receptacle (see Figure 15).

Models RGH3000 and RGH3000PR have
only the 120V, 15-amp GFCI duplex recep-
tacle.

POWER CORD AND PLUG
REQUIREMENTS

120V, 30-amp twist-lock receptacle

• NEMA L5-30P plug

• Three-wire, 30-amp cord

120/240V, 20 or 30-amp twist-lock
receptacle

• NEMA L14-20P (20-amp) or L14-30P

(30-amp) plug

• Four-wire, 20-amp or 30-amp cord

120/240V, 50-amp receptacle

• NEMA L14-50P

• Four-wire, 50-amp cord

w

G

Y

X

Ground

X

(Hot)

W

(Neutral)

Y

(Hot)

Ground
(Green)

L14-20P
Plug

120V

120V

Neutral

120/240 Volt

20 Amp

w

G

Y

X

w

G

Y

X

120V

120V

Neutral

Ground

Ground

X

(Hot)

W

(Neutral)

Y

(Hot)

Ground
(Green)

L14-30P
Plug

L14-20P
Plug

120V

120V

Neutral

w

G

Y

X

Ground L14-50P

Plug

120/240 Volt

20 and 30

Amp

120V

120V

Neutral

Figure 16 - Cord and Plug Configurations

Continued

This manual is related to the following products: