Dove Systems DM-124 User Manual
Page 4

4
When power is connected, the status LED will light up in red (60Hz line), yellow (50Hz line), and turn
green when a DMX signal is present.
C Grounding
The term "grounding" refers to a separate wire, usually with green insulation, which is connected from
the equipment case to earth ground. This is not the same as the neutral, or "common" and must not
be confused with it; the neutral is a separate, load-carrying conductor. When the pack is connected to
the power source by a flexible cable, this ground connection is made through a third wire in the cable
and the ground prong on the plug. For maximum safety, and to comply with electrical codes, this con-
nection must be made. Do not use an adapter (or "cheater") plug.
D Load Connections
The pack will dim any load from 1 watt through 2400 watts. This includes conventional incandescent
and quartz incandescent loads. Fluorescent loads can be controlled by the pack with no damage to
the dimmer, but the nature of these loads requires specialized circuitry to get full range dimming.
Consult the factory if you need to dim such loads.
Merely plug the load or an extension cord to the load into the outlet which corresponds to the circuit
you wish to use. Always use grounded cords. Loads may be single fixtures or combinations of lights
not exceeding 2400 watts.