Setup, Calibration, Capacity – Digi-Star EZ4600 User Manual
Page 51: Display count, Display units, Weigh method, Motion, Wma1-1 through wma2-3, Lft option setting, Zero/balance the scale with no load on the machine

Legal-for-Trade Certification
D3716-US REV C
EZ4600 User’s Manual
47
Sealed to Prevent Unauthorized Modifications
The scale indicator is sealed by a Category 1 Audit Trail. To access the
audit trail in the normal weighing mode, press and hold the “ON” key. This
will display the current parameter and calibration event count values.
Pressing any key will return the indicator to the weighing mode. The audit
trail system is always active and cannot be altered. Audit trails are stored
in flash memory and do not require batteries to maintain the audit trail
values.
Changing any of the following parameters will change the Calibration event
count value or parameter audit event count value. This will void your
Legal-for-Trade certification unless performed by properly trained
personnel.
•
Setup
•
Calibration
•
Capacity
•
Display
Count
•
Display
Units
•
Weigh
Method
•
Motion
•
WMA1-1 through WMA2-3
•
LFT Option Setting
On Legal-For-Trade Units Only
Perform the following procedure on an empty and clean machine before
the unit is to be “site-certified”.
•
Install the LFT indicator on the machine and connect all load cells.
•
Zero/balance the scale with no load on the machine.
•
Enter “871” and press . Press to accept.