Legal-for-Trade
Certification
46
EZ4600 User’s Manual
D3716-US REV C
LEGAL-FOR-TRADE CERTIFICATION
United States
In the US, the Legal-for-Trade certification is regulated by the National
Type Evaluation Program (NTEP). The NTEP certificate number is 08-40.
Canada
Measurement Canada is the Canadian agency that regulates Legal-for–
Trade scales. The approval number from Measurement Canada is AM-
5678C.
Legal for Trade Features
Digi-Star Legal-for-Trade indicators are modified to comply with US and
Canadian regulatory agencies. Some of these modifications are:
Load Cell Disconnect Sensor
Indicator displays
+RANGE
or
–RANGE
without flashing when load cells are
disconnected.
Hold Function
The Hold function has been disabled. (EZ3400, EZ3600 and EZ4600)
Printing
Printing weight values is not allowed while in motion, during self-
calibration, or if any error conditions such as
+range
,
Ovrcap
or
ovrflw.
are active.
Lock-On Weigh Method
Lock on weigh method (for animal weighing) cannot be enabled.
Tare
Cannot tare a negative weight.
Labeling
The capacity and division information is shown on the front of the indicator.