Operators manual – Digi-Star Cab Control 400 User Manual
Page 3

Operators Manual
D3674
1
The Cab Control 400 allows the loader operator to
communicate via radio signal to a properly equipped EZ
indicator. Once in contact with an indicator, the Cab Control
allows the loader operator to view the indicator display and
control the indicator by pressing buttons on the Cab Control
front panel.
Mounting Location
Metal structures surrounding the indicator and the Cab
Control 400 may block the radio signal. The Cab Control
400 is designed to work with the EZ indicator mounted
inside the cab of a truck and the Cab Control 400 mounted
in a loader or tractor cab at dashboard level or above.
Connecting Power
Power can be obtained directly from either a 12 Volt or a 24
Volt electrical system or for stationary applications, from a
120VAC to 12VDC power cube that plugs into a wall outlet.
Warning!
Disconnect the Cab Control 400 power cord
before jump-starting or fast-charging the
battery.
Connect the RED wire from the power cable to 12VDC or
24VDC and the BLACK wire to GROUND. The Cab Control
400 is fused internally at 2 Amps but typically uses less than
0.20 Amps. Orange and Blue wires are not connected.
Wire Color
Wire Function
RED
Battery (+12VDC)
BLACK
GROUND