beautypg.com

Setting-up the cab control 400, Setup cab control 400, Cab control 400 – Digi-Star CC400 User Manual

Page 8

background image

Cab Control 400

4

Setting-Up the Cab Control 400

The Cab Control 400 is setup at the factory. There is one selection for the buzzer, one for
AUTOFF

and twelve selections to enable or disable communications from each of the twelve

available scales. If necessary to re-configure the setup parameters, see below.

Buzzer - Turn audio alarm OFF or ON.
AUTOFF - Set Cab Control 400 to turn off after 15, 30 or 60 minutes.
SCL NO - Disable or enable each of the twelve scale selections.

Note:

Disabling unused scale selections allows the operator to avoid selecting scales
that are not in use.

Setup Cab Control 400

1. Follow steps “a” and “b” to enter the “SETUP” menu:

a. Turn the unit off.

b. Press [On] while holding either [Net/Grs] or [Select] for 8 seconds.

setup and Buzzer will show on the display followed by the current setting.

2. Press [Net/Grs] or [Select] to toggle the buzzer

on or off.

3. Press [On] to save the setting and advance to

AUTOFF.

4. Press [Net/Grs] or [Select] to select

OFF, 15, 30 or 60.

5. Press [On] to save the setting and advance to the next selection.

6. Press [Net/Grs] or [Select] to enable (

Y) or disable (N) each of the twelve available

scales.

7. Press [On] to save the setting and advance to the next selection.

8. After scale number twelve has been set, press [On] to exit or [Net/Grs] to run self-

test.


Example below illustrates how to set up a system with two scales.

Buzzer is set to on,

Autoff

is set to 60 minutes and Scale #1 and Scale #2 are enabled:

buzzer - on
autoff - 60
scllst

sco1-y

sco5-n

sc09-n

Sco2-y

sco6-n

sc10-n

sco3-n

sc07-n

sc11-n

sco4-n

sc08-n

sc12-n

NOTE:

On systems with six or less scales, use scales numbered 1 through 6.