Setting-up the cab control 400, Setup cab control 400, Cab control 400 – Digi-Star CC400 User Manual
Page 8

Cab Control 400
4
Setting-Up the Cab Control 400
The Cab Control 400 is setup at the factory. There is one selection for the buzzer, one for
AUTOFF
and twelve selections to enable or disable communications from each of the twelve
available scales. If necessary to re-configure the setup parameters, see below.
Buzzer - Turn audio alarm OFF or ON.
AUTOFF - Set Cab Control 400 to turn off after 15, 30 or 60 minutes.
SCL NO - Disable or enable each of the twelve scale selections.
Note:
Disabling unused scale selections allows the operator to avoid selecting scales
that are not in use.
Setup Cab Control 400
1. Follow steps “a” and “b” to enter the “SETUP” menu:
a. Turn the unit off.
b. Press [On] while holding either [Net/Grs] or [Select] for 8 seconds.
setup and Buzzer will show on the display followed by the current setting.
2. Press [Net/Grs] or [Select] to toggle the buzzer
on or off.
3. Press [On] to save the setting and advance to
AUTOFF.
4. Press [Net/Grs] or [Select] to select
OFF, 15, 30 or 60.
5. Press [On] to save the setting and advance to the next selection.
6. Press [Net/Grs] or [Select] to enable (
Y) or disable (N) each of the twelve available
scales.
7. Press [On] to save the setting and advance to the next selection.
8. After scale number twelve has been set, press [On] to exit or [Net/Grs] to run self-
test.
Example below illustrates how to set up a system with two scales.
Buzzer is set to on,
Autoff
is set to 60 minutes and Scale #1 and Scale #2 are enabled:
buzzer - on
autoff - 60
scllst
sco1-y
sco5-n
sc09-n
Sco2-y
sco6-n
sc10-n
sco3-n
sc07-n
sc11-n
sco4-n
sc08-n
sc12-n
NOTE: