Operating the cab control 400, Cab control 400 keys, Turn on the cab control 400 – Digi-Star CC400 User Manual
Page 6: Cab control 400

Cab Control 400
2
Operating the Cab Control 400
Cab Control 400 Keys
Three of the four Cab Control 400 keys have dual function. The function listed on the top of
the key is actuated by momentarily pressing the button. The function listed on the bottom of
the key requires the operator to “press and hold” the key.
Zero .................... Press momentarily.
Print .................... Press momentarily.
Tare .................... Press for 1-1/2 seconds.
Net/Grs ............... Press momentarily.
Select .................. Press for 1-1/2 seconds.
On ....................... Press momentarily.
Off ....................... Press for 3 seconds.
NOTE:
Use the “Print” key on the Cab Control 400 to advance ingredient when in the
batching mode.
Turn on the Cab Control 400
Press [On].
-
A brief hello and Cab Control message will be displayed.
-
If no signal is being received, the indicator will flash NODATA and the scale number.
Example:
SCL 2.
-
If a signal is being received, the Cab Control 400 display will match the display on the
scale.
-
Pressing a key on the Cab Control 400 front panel causes that key-press to be
entered on the scale indicator.
NOTE: To turn Cab Control 400 off, press and hold [On/Off] until “
BYE
” is displayed. Scale
indicator cannot be turned on or off from the Cab Control 400.
Zero
Print and Tare
On/Off
Net/Gross and Select