Menu 3. scale calibration settings – Digi-Star EZ 4600 Manual DataKey User Manual
Page 40

Menus and Calibration
36
EZ4600 User’s Manual
D3716-US REV D
SETTING
[display]
D.A.N
NO.
OPTIONS [displayed]
BOLD=DEFAULT
DESCRIPTION
SCALE NUMBER
(SCL NO)
231
Select scale number for
cab control
communication
REMOTE
DISPLAY
(RMDISP)
234
Select type of remote
display
MENU 3. SCALE CALIBRATION SETTINGS
DISPLAY UNIT
(lb-kg)
303
LB
/KG
Display pounds -lb or
kilograms -kg
MIMIC TYREL
(tcI300)
321
OFF
/ON
If ON -records preset
weights like a TYREL
TCX-1300 indicator.
Indicator Tracks gross
weight while batching.
MENU 4. PRESET. BATCHING & ROTATION COUNTER FEATURES
PRE ALARM
(p mthd} & {p-alm)
401
WEIGHT
PERCNT
Select weight or
percentage method, then
enter a value to activate
an early warning that
indicator is reaching the
preset.
BUZZER
(buzzer)
404
1-4,
ON
/OFF
ALARM BUZZER -allows
user to turn off alarm horn.
TIMER/
COUNTER
(tmrctr)
421
REV
TIME
Select time or mixer
revolutions to decrement
mix timer/counter.
DRIVE RATIO
(dratio)
422
0001.00
Enter the number of input
pulses that equal 1 mixer
revolution.
MANUAL
PROGRAMMING 439
PC
/SCALE
PC: Requires a Datakey
with programming.
Scale: Allows user to
manually program
indicator.
ENTRY METHOD
(E MTHD)
441
1
,2,3
Select batch 1-
amount/animal
2-percent/load
3- amount/load
TOLERANCE
(toler)
442
OFF
,.5,1-5,7,10
Select tolerance weight
percentage to accept
ingredient.