Menu 3. scale calibration settings – Digi-Star EZ 3600 Manual DataKey User Manual
Page 39

Menus and Calibration
D3715 Rev D
EZ3600 User’s Manual
35
SETTING
[display]
D.A.N
NO.
OPTIONS [displayed]
BOLD=DEFAULT
DESCRIPTION
REMOTE DISPLAY
(RMDISP)
234
Select type of remote
display
MENU 3. SCALE CALIBRATION SETTINGS
DISPLAY UNIT
(lb-kg)
303
LB
/KG
Display pounds -lb or
kilograms -kg
MIMIC TYREL
(tcI300)
321
OFF
/ON
If ON -records preset
weights like a TYREL
TCX-1300 indicator.
Indicator Tracks gross
weight while batching.
MENU 4. PRESET, BATCHING & ROTATION COUNTER FEATURES
PRE ALARM
(p mthd) & (p-alm)
401
WEIGHT
PERCNT
Select weight or
percentage method, then
enter a value to activate
an early warning that
indicator is reaching the
preset.
BUZZER
(buzzer)
404 1-4,
ON
/OFF
ALARM BUZZER -allows
user to turn off alarm
horn.
TIMER/
COUNTER
(tmrctr)
421
REV
TIME
Select time or mixer
revolutions to decrement
mix timer/counter.
DRIVE RATIO
(dratio)
422
0001.00
Enter the number of input
pulses that equal 1 mixer
revolution.
MANUAL
PROGRAMMING
(Program)
439
PC
/SCALE
PC: Requires a Datakey
with programming.
Scale: Allows user to
manually program
indicator.
ENTRY METHOD
(E MTHD)
441
1
,2,3
Select batch 1-
amount/animal
2-percent/load
3- amount/load
TOLERANCE
(toler)
442
OFF
,.5,1-5,7,10
Select tolerance weight
percentage to accept
ingredient.
INGR. ADVANCE
DELAY
(delay)
443
MANUAL
, 1-3,5,7,
10,20,30,60
Select seconds to delay
before advancing to next
ingredient.
FORCE USER ID
(userid)
446 ON/
OFF
If ON -operator must enter
user ID to use indicator.