Digital I/O Power Select

2-3 On: +5V

1-2 On: +5V_standby

(default)

JP13 is used to select the power of DIO (Digital I/O) signal.

JP13

1

3

2

1

3

2

Digital I/O Output State

Based on the power level of DIO (Digital I/O) selected on JP13, JP10 (DIO pin 0-3) and JP12

(DIO pin 4-7) are used to select the state of DIO output: pull high or pull low. When selecting

pull high, the power selection will be the same as JP13’s setting.

2-3 On: GND

(default)

1-2 On: +5V or

+5V_standby

DIO 0-3

(JP10)

DIO 4-7

(JP12)

1

3

2

1

3

2